Schneider Electric Acti9 A9D32620 Residual Current Breaker with Overcurrent Protection (RCBO)
Schneider Electric Acti9 A9D32620 Residual Current Breaker with Overcurrent Protection (RCBO)
A9D32620
Residual current breaker with overcurrent protection (RCBO), Acti9, iDPN N Vigi, 1P+N, 20A, C curve, 6000A, A type, 30mA
This Acti9 iDPN Vigi is a modular residual current breaker with overcurrent protection (RCBO). It has 2P with 1 protected pole, 20A rated current and C tripping curve. This A type device has 30mA sensibility. Breaking capacity at 230VAC is 6000A according to IEC 61009-1. This product protects against short circuit, cable overload, electrical shock by indirect contact and fire hazards. Its earth fault indicator on front face allows quick identification of the type of default. It brings safety and reliable solution for commercial and industrial applications. This product is compliant with EN/IEC 61009-2-1 standard. It offers 2 VisiTrip window to reduce intervention time and VisiSafe for safe intervention. The Ue operational voltage is 220VAC to 240VAC. The Ui rated insulation voltage is 400VAC. The Uimp rated impulse withstand voltage is 4kV. The frequency is 50Hz. It is DIN rail mountable. The width in 9mm pitches is 4. The product color is white (RAL9003). The dimensions are (W) 36mm x (H) 85mm x (D) 73mm. The weight is 125g. It has an IP20 degree of protection. It becomes IP40 once in modular enclosure according to IEC/EN 60529 standard. The operating temperature is from -25°C to 60°C. The storage temperature is from -40°C to 85°C.
Specifications
Specifications
Range: Acti9
Product name: Acti9 iDPN Vigi
Product or component type: Residual current breaker with overcurrent protection (RCBO)
Device application: Distribution
Poles description: 1P + N
Number of protected poles: 1
Neutral position: Left
[In] rated current: 20 A
Network type: AC
Network frequency: 50 Hz
Trip unit technology: Thermal-magnetic
Curve code: C
Earth-leakage sensitivity: 30 mA
Suitability for isolation: Yes conforming to EN/IEC 60947-2
Device location in system: Outgoer
[Ue] rated operational voltage: 230...240 V AC 50 Hz
Magnetic tripping limit: 5...10 x In
Residual current tripping technology: Voltage independent
Earth-leakage protection time delay: Instantaneous
Earth-leakage protection class: Type A
Breaking capacity: 6000 A Icn at 230...240 V AC 50 Hz conforming to EN/IEC 61009-2-1
[Ics] rated service breaking capacity: 6000 A 100 % x Icn at 230...240 V AC 50 Hz conforming to EN/IEC 61009-2-1
Rated breaking and making capacity: Idm 6000 A at 230...240 V AC 50 Hz conforming to EN/IEC 61009-2-1
Limitation class: 3 conforming to EN/IEC 61009-2-1
[Ui] rated insulation voltage: 400 V AC 50 Hz
[Uimp] rated impulse withstand voltage: 4 kV
Contact position indicator: Yes
Control type: Toggle

$60.50